Jornada
Published on Jornada (https://jornada.nmsu.edu)

Home > Using time-series intervention analysis to model cow heart rate affected by programmed audio and environmental/physiological cues

Using time-series intervention analysis to model cow heart rate affected by programmed audio and environmental/physiological cues [1]

TitleUsing time-series intervention analysis to model cow heart rate affected by programmed audio and environmental/physiological cues
Publication TypeConference Proceedings
Year of Publication2010
AuthorsAnderson D.M. [2], Remenyi N. [3], Murray L.W. [4]
Conference NameApplied Statistics In Agriculture Conference Proceedings
Pagination107-136
Date Published2010
PublisherKansas State University
Conference LocationManhattan, Kansas
ARIS Log Number257429
Keywordsaudio cue [5], direction virtual fencing [6], DVM [7], free-ranging beef cattle [8], heart rate [9], Polar hear rate monitors [10], time-series analysis [11]
Abstract

This research is the first attempt at using time -series analysis to describe changes in the heart rate (HR) of free-ranging cows receiving programmed audio cues from directional virtual fencing (DVF™) devices designed to control the animal's location on the landscape as well as non-programmed environmental/physiological cues. Polar Accurex® devices were used to capture HR every minute between March 19-24, 2003 when three mature free-ranging beef cows previously habituated to DVF™ control were confined to a brush-infested area of an arid rangeland paddock. Global positioning system (GPS)electronics were used to locate each cow's location approximately every minute while it was in a 58 ha virtual paddock (VP™) and every second when it penetrated a virtual boundary (VB™). The cows never escaped through the VB™ though they penetrated it a total of 26 times in 11 different events at which time they received programmed audio cues lasting from 1 to 56 s. These data reveal that HR spikes from programmed audio cues all fell within the textbook range for cow HR (40-186 beats per minute, bpm). For both audio and selected evironmental /physiological events, HR spikes returned to pre-cuing "baseline" values in about one minute. However, the longest return time to baseline lasted (about 4 minutes) and this was for an environmental/physiological event. HR, animal location, weather and other electronic data should be measured at equally-spaced time intervals using a single time stamp so as to accurately associate HR changes with possible causes.

URL/files/bibliography/10-045.pdf [12]

                      

Contact Us   |   Agricultural Research Service   |   ARS News and Information   |   Statements and Disclaimers   |   Freedom of Information Act


Source URL: https://jornada.nmsu.edu/biblio/using-time-series-intervention-analysis-model-cow-heart-rate-affected-programmed-audio-and-0

Links
[1] https://jornada.nmsu.edu/biblio/using-time-series-intervention-analysis-model-cow-heart-rate-affected-programmed-audio-and-0
[2] https://jornada.nmsu.edu/biblio?f%5Bauthor%5D=1
[3] https://jornada.nmsu.edu/biblio?f%5Bauthor%5D=280
[4] https://jornada.nmsu.edu/biblio?f%5Bauthor%5D=281
[5] https://jornada.nmsu.edu/biblio?f%5Bkeyword%5D=394
[6] https://jornada.nmsu.edu/biblio?f%5Bkeyword%5D=395
[7] https://jornada.nmsu.edu/biblio?f%5Bkeyword%5D=396
[8] https://jornada.nmsu.edu/biblio?f%5Bkeyword%5D=397
[9] https://jornada.nmsu.edu/biblio?f%5Bkeyword%5D=398
[10] https://jornada.nmsu.edu/biblio?f%5Bkeyword%5D=399
[11] https://jornada.nmsu.edu/biblio?f%5Bkeyword%5D=400
[12] https://jornada.nmsu.edu/files/bibliography/10-045.pdf